蛋白樣品制備
蛋白樣品制備
蛋白樣品制備
Protein Co
ncentrators PES, 10K MWCO, 0.5mL
描述 Thermo Scientific Pierce Protein Co
ncentrators PES are disposable ultrafiltration centrifugal devices with a polyethersulfone (PES) membrane for concentration, desalting and buffer exchange of biological samples. This product has a molecular-weight cutoff of 10K, and can be used for processing sample volumes up to 0.5 mL.
Features of Pierce Protein Co
ncentrators PES:
? Rapid protein concentration—sample co
ncentration of 10- to 30-fold can be achieved in 10 minutes or less
? Excellent protein recovery—unique design minimizes membrane fouling and provides high speed concentrations, even with particle laden solutions
? Instrument-compatible—use standard microcentrifuge with fixed-angle rotors; collect and recover sample without invert spinning
? Versatile—easy way to perform sample concentration, diafiltration or buffer-exchange of biological samples
For easy identification, the MWCO value is etched on the side of each device. To assist with sample addition and recovery, a clear window with graduations is located on the side of each device enabling visual determination of the retentate volume. The vertical design of the membrane allows high flux rates, low non-specific binding and negligible protein aggregation on the membrane and provides reliable and co
nsistent results for processing sample volumes between 100 and 500 μL. Typical protein recovery is 90% when the mass of the proteins in the sample is at least two-fold greater than the MWCO of the device used. Sample co
ncentration of 10- to 30-fold can be achieved within 10 minutes.
Applications:
? Protein co
ncentration with tissue culture media, antiserum or mo
noclonal antibody preparations
? Co
ncentration of protein peaks following gel-permeation chromatography
? Removal of unincorporated label following protein modification reactions
? Co
ncentration and desalt/buffer-exchange after eluting protein from ion-exchange, hydro
phobic interaction (HIC), me
tal chelate or affinity chromatography columns
? Separating large molecules from small molecules
Pierce Protein Co
ncentrators PES co
ntain a membrane rated for retaining molecules with a molecular weight at least two-fold greater than the MWCO rating of the PES membrane within the device. Reduced recovery may occur when using a co
ncentrator with molecules smaller than the recommended mass. Protein recovery will vary depending on the specific protein in the sample and its starting concentration. To achieve >90% recovery of protein, the minimum protein sample co
ncentration should be 0.05 mg/mL.
Pierce Protein Co
ncentrators PES allow accurate co
ntrol of the dead-stop volume (15 μL) and final co
ncentration factor, providing reliable and co
nsistent sample processing. They can be used effectively at a maximum centrifugal force of 15,000 x g at room temperature. Centrifugal force, temperature and sample volume, co
ncentration and viscosity affect filtration rate. Optimize centrifugal time for each application.
官網鏈接:https:///order/catalog/product/88513?SID=srch-hj-88513

本頁產品地址:http://m.lgsztm.com/sell/show-8836630.html